Home >> Application >> Lab Chiller
Lab water AAS chiller
  • Lab water AAS chiller
Lab water AAS chiller

Lab water AAS chiller

HanChiller(H) was designed with high quality, complete configuration, perfect protection, warning system, particularly for high-end analytical instruments. They are equipped with selective water purification devices, alarm protection of water flow, level and overheat.Chiller technology is the driving force of enterprise development.

Product Details

HanChiller(H) was designed with high quality, complete configuration, perfect protection, warning system, particularly for high-end analytical instruments. They are equipped with selective water purification devices, alarm protection of water flow, level and overheat.Chiller technology is the driving force of enterprise development. Only by adhering to innovation can we inject fresh blood into the enterprise and make it take the leading position in the industry. As we all know, the main components of a chiller are four major parts: compressor, evaporator, condenser and expansion valve. In order to make the chiller durable and refrigerating fast/well, we must improve the technology.Cold water machine is a vapour compression or absorption cycle through the machine of refrigeration effect. These fluids can flow through a heat exchanger to cool air or equipment. Steam compression chillers consist of four main components of the steam compression refrigeration cycle, and these machines can realize different refrigerants. HanChiller(H) gets the CE certification, can match all kinds of power interface, can export all over the world.


Feature

◎ Intelligent PID temperature control with high precision;

◎ Vertical appearance design with beautiful shape, compact volume and small area

◎ Automatic start-up can be set with software;

◎ Standard configuration for water level alarm system;

◎ Large, easy to read temperature display lets you check operation at a glance


Application

The chiller can apply to AAS equipment in Lab. The graphite heating electrode needs to be cooled and protected in the working process of the atomic absorption graphite furnace, and the graphite tube needs to be cooled to room temperature quickly after working, prepare for next sample analysis.


Performance specification

ModelCoolingCapacity
W
Temperature Range
TemperatureStability
Circulating Pressure
bar
Circulating Flow
L/min
Quantity
L
SizeofcommunicationRCOverall DimensionW x D x H mm
H19005~35±0.10.8~3.65~3081/2300*506*710
H220005~35±0.11.3~5.45~30161/2360*566*860
H332005~35±0.11.9~5.48~50261/2420*636*950
H446005~35±0.11.9~5.48~50401/2480*720*1016
H556005~35±0.11.9~5.48~50601/2530*780*1066